Engineering Instructions PDF:

View file
namePAX_S-2.3.3 X UpgradeInstructions.pdf

Instructions addendum:

...

Shuttle calibration is retained; however, the insert offset will need to be reset for each Pax Shuffler.

Important: The shuttle insert calibration must be set with the calibration marks in alignment. Version 2.3.3 and future releases will no longer needs to subtract calibration numbers after aligning, as described in an earlier technical bulletin.

...

  1. In the Utilities menu select USB import / Export

  2. Plug a Fat32 formatted USB drive in the port on the Pax Shuffler

  3. Select Export Settings.
    Note: The serial number will auto populate as the export name. There is no need to change this name.  If you do change the name, do not add, or leave any spaces in it.

  4. Press return on the digital keyboard, start and confirm.

  5. Remove USB drive and proceed to the next shuffler.

  6. Plug USB drive into Pax Shuffler to transfer settings.

  7. Navigate to USB Import / Export in the Utilities menu and select import.

  8. Select the file name of settings to import. Press Start, Press Confirm.

  9. Repeat the previous four steps for all Pax Shufflers at location.

...