2015 Logic Box

When the logic box boots up it will make an audible beep to indicate the PC will output video.

C020788 2015 Logic Cartridge Assembly Non-Secure Boot (bios chip has red, orange and silver dots)
C020789 2015 Logic Cartridge Assembly Secure Boot (bios chips dots are yellow for 1.3 and white for 1.4)

Connections

Outside:

❖ USB All USB ports are interchangeable.
❖ Network use the port on the left when connecting to a server. The port on the right is unused.

❖ Comm port The port at the back of the logic is for any accounting equipment.
❖ Green port
❖ Video card Use the HDMI port for any LCD button deck.

Inside:

  • Red Circle - Ribbon cable hiding the NV Ram Battery.

  • Yellow Circle - 2032 CMOS Battery. Logic Intrusion switch.

  • Blue Circle - Temp Sending Board. Controls the speed of the fan on the side of the logic. If the game is shutting down for no reason, disconnect this board and see if it stays running.

  • Green Circle - Intrusion Switch

  • Yellow Square - Bill Vailidator

  • Green Square - Printer

  • Green Arrow - Active USB ports on Adapter board. Do not use unless necessary.

  • Sata Ports -

    • Class3
      ▪ Top Left port is for the boot drive.
      ▪ Bottom Right port is the game SSD.

    • o Class2
      ▪ Top left Is for the SSD.


Perform a RAM Clear Class 3

Atlas: For initial setup, the game needs to power up with the System CF installed until the game shows a Fatal File Error Problem reading Jurisdiction.xml.

Atlas 3D: Ram Clear the game first. There is no error indicating the Jurisdictional file is missing until you have completed setup. If the game is not Ram Cleared first the game will show 12.10 and require a Ram Clear.

  1. Power the Game Off.

  2. Open the main door, and then the Logic door.

  3. Remove the System CF and Insert the RAM Clear CF module into the System CF Module slot.

  4. Power the game on and it will go through the RAM clear process.

  5. When the CPU Fan shuts off or you cannot hear anything happening in the logic box, the RAM Clear is done.

  6. Turn the cabinet off after it finishes the RAM Clear process.

  7. Remove the RAM Clear CF and Insert the System CF module.

  8. Power the game on and continue with the initial configuration.


Perform a Ram Clear Class 2

Class II Ram Clear should not be done by the technician through the menu as it does not perform Ram Clear.  If the cabinet is needed to Ram Clear, please call Technical Assistance at 1(877) 358-6300 to perform Ram Clear.


Unable to render {include} The included page could not be found.

Unable to render {include} The included page could not be found.

Attendant Light / Candle

C050850 Attendant light board


Saving Logs into USB flash drive

To pull logs on a class 3 Atlas or Atlas 3D game you need to have a USB formatted Fat 32.

  1. With the cabinet powered on, insert the usb into any open port on the logic box.

  2. Enter the tech menu (Red Key) and go into the Control Menu.

  3. Select Save Logs to USB. You should see a message either saying it did or did not work.

  • Following example illustrates Atlas 3D Game (Step by Step Screen Shots) USB capture on NextGen Cabinet

  • Following example shows Atlas Player screen shot for your reference.


Error rendering macro 'viewxls' : The space key could not be found.

  • No labels

0 Comments

You are not logged in. Any changes you make will be marked as anonymous. You may want to Log In if you already have an account.