If Auto configure does not work or there is an error in the bottom left corner, log into the controller and open quick config. If auto config is available, auto config the EPS.

Note

Before doing any additional steps, make sure you have completed one reboot of the controller through the start menu.

If these steps do not work, you may need to verify the progressivecontroller.xml file.

If the file is empty, copy and paste the info listed below this picture and save.

Warning

IF THE FILE IS NOT EMPTY DO NOT CHANGE THE FILE. IT IS NOT THE PROBLEM

unless every word in the document is NULL NULL NULL, then it is the problem.

...

Code Block
<ProgressiveController>
  <DoProgressive>true</DoProgressive>
  <ForcedBroadcast>
    <BroadcastAddress>10.0.5.1</BroadcastAddress>
    <BroadcastPort>4503</BroadcastPort>
    <IsUnicast>false</IsUnicast>
  </ForcedBroadcast>
<PortAssignment/>
<MaestroPortAssignment/>
</ProgressiveController>

...

  1. Remove the game from Progressive Manager

  2. Delete the game from Quickconfig

  3. Delete the game from dhcpmanagement

    Image Added
  4. Shut the game off

  5. Restart the Progressive Controller

  6. Turn the game on

  7. Auto-config at the game.

...

Follow the steps above and if they do not work, Support will need to assist with a solution. If the games were communicating with the controller before the controller was finished with the upgrade this error will occur and the controller will need to be reset.