All themes for the Spectra cabinets are supposed to have the topper content on the SSD so the topper will run with the on-board video port.
Warning |
---|
Sometimes the |
content doesn’t show on the topper. |
Solution:
What to do when the topper does not work:
Reboot a couple times.
Try the top port instead of the bottom one.
Order new SSDs.
Tip |
---|
Upgrade the topper firmware. |
**Firmware update instruction**
https://youtu.be/Ed5V64tMRWAIn testing we did not have to install any drivers.
View file | ||
---|---|---|
|
Tools: Waiting to distribute the tools.
Laptop with Windows 10 or 11
SP Tool Software Alpha Display HSO.zip
MStar Tool
VGA cable
USB A-B
Programming file (*.bin)
On the target laptop plug one end of the USB and the other in the MStar tool.
Connect VGA cable from MStar Tool to Monitor (Monitor must be powered on)
Run ISPTool.exe
Check "Use USB" and "Auto release USB" in Config menu of ISP_Tool
Select the “Read” menu and select the target firmware
Click “Connect” button. If connection is correct, Device Type. If not, please click Dis Con button then Connect button again.
Select ‘Auto” menu and ensure all selections match as below. Click Run.
Check to see if programming complete. PASS