AGS Field Service Knowledge Base

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

HHR_3D Initial Configuration Procedure 

Please ensure the required connections are established prior to following the configuration procedure 

  • Active network connection between cabinet and HHR server 

  • Active SAS connection to the cabinet 

Initial configuration instruction procedure: 

  1. Insert System CF and Game SSD into Logic Case and turn the cabinet On

  2. When the game comes up, it will show a config error 

  3. Turn the cabinet Off and remove System CF 

  4. Insert RAM Clear CF into the System CF slot and turn the cabinet On 

  5. The game will run through RAM Clear steps and the display will turn off after its complete 

  6. Turn the cabinet Off, remove the RAM Clear CF, insert the System CF and turn the cabinet On 

  7. On the Server Configuration screen, in the address bar, enter the HHR Server URL and press Connect to URL 

  8. On the Game Configuration screen, enable the denomination and select the desired payout and press Done  : Please refer to the Game PAR sheet to set the correct desired hold configuration.  For example, setting 90% configuration is not actually 10% hold, it is less due to progressives. 

  9. Open Main door and Logic door and continue through remaining configuration 

  10. On the Configuration Setup menu, press Machine Settings  

  11. Press Machine Configuration, set the desired settings, press Save and then Back 

  12. Please ensure the Machine Number is unique for the Exacta system NOTE: Please ensure the Machine Number is unique for the Exacta system 

  13. Press SAS Settings, configure SAS settings as desired by the customer, press Save and then Back 

  14. Press Credit Limits, verify limits, press Save and then Back 

  15. Press Bill Limits, verify limits, press Save and then Back 

  16. Press Server Settings, press Save and then Back  

  17. Press Back to go back to the Configuration Setup screen 

  18. Press Time Settings, verify/set current date and time (24hrs format), and press Save and then Back 

  19. Press Finish Configuration 

  20. Close Main door and Logic door 

  21. The game screen will load once all configuration is set and all necessary connections are established 

  • No labels