The 3-Month PM is more extensive and requires the cleaning and replacement of certain components; mainly the elevator/swing arm pads. The worm Gear must be *lubricated at this time. Reference pages 20-26 of the DexS manual for these detailed instructions.

3 month pm

  1. remove front and back covers

  1. blow shuffler out with data vac

  1. clean sensors

  1. clean rollers

  1. replace elevator pads (C40-000254 quantity 2)

  1. lube worm gear

*Important; when lubricating the Worm Gear, use only DRY LUBRICANT with PTFT or Teflon as clearly noted on page 25 of the DexS service manual. *

  1. clear cycles and logs

  1. test

  1. wipe down top and covers with glass cleaner

 10. install covers