Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Class 3:

  • Serial number doesn’t match from last reboot. This randomly happened on a cabinet. Check smartID and refresh. Then reboot.

  • Saw this happen on Spectra Cabinets when a customer was running 21.2 instead of 23.1 which is the lowest version approved for the cabinet.

This error also shows up if there is a short in the cabinet. Disconnect all cables not needed to boot the cabinet and see if the error goes away. As of 8/10/2023 we have had two bad candles or candle wires cause this error.

...