Class 3:
Serial number doesn’t match from last reboot. This randomly happened on a cabinet. Check smartID and refresh. Then reboot.
Saw this happen on Spectra Cabinets when a customer was running 21.2 instead of 23.1 which is the lowest version approved for the cabinet.
This error also shows up if there is a short in the cabinet. Disconnect all cables not needed to boot the cabinet and see if the error goes away. As of 8/10/2023 we have had two bad candles or candle wires cause this error.
...