Omni (Axiomtek Sign Controller (AXIOM-SC)) Instructions.

EPC and a Sign controller work with OS_24.2 and newer only.

  1. Connect the “Game” network port on the sign controller to the switch with the games.

  2. Connect the “non-game” network port to your laptop.

    1. Set the laptop IP address to a static:

      1. 10.0.8.8

      2. 255.255.252.0

    2. Remote into 10.0.8.9 and continue setup on the sign controller.

On the Cabinet, in the Game Content Sync menu set the Sign Address to the name of the sign controller. It should match the label on the front of the controller.

Game sync.jpeg

 

IMG_9743 Large.jpeg

 