AGS Field Service Knowledge Base

Firmware Manifests XML missing

This error occurs when the game is not seeing the CLS.

 

On the curve cabinet if the CLS is replaced and it has the 1.16 firmware it may burn out when it connects to the new eclipse on the main door. The new curve eclipse is a parallel circuit and each LED has a chip that runs it.

There is a new firmware 1.18 that can run the series and parallel led lights on the Curve.

Parallel Eclipse board needs 1.17 CLS

Series Eclipse board needs 1.16 CLS

 

For assistance email support@playags.com or call 1-877-358-6300