AGS Field Service Knowledge Base

36.0

Problem

36.0 Main Door (Deck) Open. This is not the main door or the deck it is actually for the cherry switch behind the cash box.

Solution

  • Either the cash box has been removed causing the door open error.

  • Cherry switch behind the cash box is wired incorrectly.

  • There is a loop back connector on the Yellow wires of the intrusion harness. That loop back connector needs to be installed for it to see the door as closed. This is required when the cherry switch is not installed behind the cash box (most jurisdictions). If the loop back is missing, just short the wires together.

 